Optimization and characterization of a new microextraction device for determination of phenols in water samples

Abu-Alsoud, Ghadeer Fouzi (2021) Optimization and characterization of a new microextraction device for determination of phenols in water samples. Doctoral (PhD) thesis, Memorial University of Newfoundland.

[img] [English] PDF - Accepted Version
Available under License - The author retains copyright ownership and moral rights in this thesis. Neither the thesis nor substantial extracts from it may be printed or otherwise reproduced without the author's permission.

Download (5MB)

Abstract

Porous water-compatible molecularly imprinted polymer coatings with selective binding sites for extraction of phenols from environmental water samples were prepared on glass using an optimized mixture of water-soluble carboxylic acid functional monomers, ethylene glycol dimethacrylate crosslinker, catechol as a pseudo-template, and a porogen system of methanol/water with linear polymer polyethylene glycol. The MIP devices were combined with ultra high-performance liquid chromatography with a photodiode array detector suitable for the simultaneous determination of trace levels of phenol, alkylphenols and chlorophenols in seawater (SW) and produced water (PW). For effective imprinting, the MIP formulation was optimized through systematic optimization of critical factors like the nature and the amounts of functional monomer, crosslinker, template, and porogen. To improve the analytical method, the parameters that influence extraction, including salinity, pH, adsorbent mass, desorption solvent, and desorption time were optimized. Under the optimized conditions, the detection limits ranged from 0.1 to 2 μg L-1, and enrichment factor between 12.8 and 133.5. The recoveries from spiked samples ranged from 85 to 100% with %RSDs of 0.2–14% for SW and 81–107% with %RSD of 0.1–11% for PW. The MIP device is simple, robust, inexpensive can be used in automation and high throughput sample processing. To better understand the performance of MIPs, four different isotherm models were used to study molecular recognition of five phenols on catechol imprinted polymer and cross-reactivity for 11 phenolic compounds through individual and simultaneous adsorption process, respectively. It was found that heterogeneity is a relative phenomenon depending on the chemistry of the adsorbates. The Langmiur-Freundlich isotherm model successfully explains the adsorption behaviour for small phenols and fails to explain the molecular recognition for the large phenols, while the BET isotherm successful in that and suggests formation of multilayer. It was observed that the competition of phenols for the binding sites of the catechol imprinted polymer depends on their hydrophobicity and solubility in water. In this work, we proved that a single isotherm model is not enough to explain the behaviour of the analytes toward adsorbent surface. Each model gives valuable quantitative data that help to explain the recognition mechanism for the adsorbates.

Item Type: Thesis (Doctoral (PhD))
URI: http://research.library.mun.ca/id/eprint/14997
Item ID: 14997
Additional Information: Includes bibliographical references.
Keywords: Thin-film molecularly imprinted polymer, Environmental water samples, Phenols, Adsorption isotherms, multilayer adsorption, Molecularly imprinted polymer cross-reactivity, MIP formulation
Department(s): Science, Faculty of > Chemistry
Date: February 2021
Date Type: Submission
Digital Object Identifier (DOI): https://doi.org/10.48336/55x9-8t76
Library of Congress Subject Heading: Water--Organic compound content; Molecular imprinting; Phenols.

Actions (login required)

View Item View Item

Downloads

Downloads per month over the past year

View more statistics